CRC221-1 ONLINE SINGLE DOOR CONTROLLER
CRC221-1
'The Single Door Option'
The CRC221-1 single-door controller is part of a range of versatile modular on-line access control panels suitable for controlling access points such as doors and vehicle barriers by validating credentials such as cards, key fobs and vehicle tags.
PRODUCT FEATURES & BENEFITS
These controllers are components of an online access control system linked to Norpass3 Access Control Management Software via either TCP/IP or RS485.
The CRC221-1 can be used to control access through a single door or barriers with read-in and read-out control while supporting a wide range of managed access control features and a comprehensive range of interface formats. The enclosure houses a single-door interface module plus an integral power supply unit.
benefits
- Easily managed using simple centralised management of data
- Choice of mix and match module types enables cost-effective network structure
- Support for a wide range of card formats and card reader interfaces makes it the ideal choice for enhancing an existing access control system
- Security levels can be tailored to customer needs using optional security features
- Improved visitor card management when used with our card capture reader
- Meets demanding customer requirements through a choice of enclosures with tamper alarms fitted as standard plus features such as fire alarm control input, individual door alarms and configurable inputs and outputs.
Connect
Contact Us
+44 (0)1633 485 533
Specifications
Electrical
| Supply Voltage: |
Enclosures: 240V AC |
| Current Requirement: | 100 mA quiescent, 230 mA while reading (both readers) |
| Reader Supply: |
12V DC (100 mA max.) 5V DC option |
Physical
|
Local settings: |
DIP switches for setting node identity |
| Dimensions (mm): |
PCB: 115 x 120 x 35 (H x W x D) |
| Cable Termination: | Plug-in screw terminal blocks |
Environmental
| Operating Temperature: | 0°C to 40°C |
| Storage Temperature: | -20°C to 70°C |
| Relative Humidity: | 95% non-condensing |
Capacity
| Sequential Mode: | 65,000 sequential card numbers (0 - 19,999), 1,700 events |
| Random Mode: | 8,000 random card numbers, 1,300 events |
data communications
| Management Interface: | RS485 or TCP/IP depending upon model |
Inputs
| Readers: | 2 x 5-wire reader interfaces for Clock & Data (ABA Track 2) & Wiegand formats |
| Arming: | 2 independent, ground activated inputs. Open-circuit arming. |
| Door Open Monitor: | Ground activated input for monitoring door open status. |
| Request to Exit: | Ground activated input. |
| Tamper Input: | Ground activated input from tamper switch on housing (where applicable). |
Outputs
| Latch Relays: | Latch relays with change-over contacts rated at 2A at 30V DC. |
| Auxiliary Output: | 2 independent open-collector outputs for auxiliary control such as card capture. |
| Tamper Alarm: | Open-collector output (300mA), activated when tamper alarm is active. |
| Door Alarm: | Door alarm is shared with the tamper alarm output. |
| Assignable Output: | Open-collector output controlled from Norpass3 in online operation. |
Cabling
| CRC200 to reader: | Belden 9536 or equivalent (100m maximum) |
| RS485 comm’s: | Belden 9729 or equivalent (1,200m maximum overall length) |
Read-In/Read-Out Security for Single High-Traffic Access Points
The CRC221-1 is purpose-built for locations requiring full bidirectional credential verification at a single door—such as server rooms, executive suites, research laboratories, or pharmacy storage areas.
By validating credentials on both entry and exit, facilities gain complete audit trails and can enforce strict anti-passback policies that prevent tailgating and credential sharing.Corporate headquarters commonly deploy CRC221-1 controllers at data centre doors where compliance regulations mandate documented access logs.
Healthcare facilities use them for medication storage rooms where both entry and departure must be recorded.
The controller's fire alarm input ensures automatic door release during emergencies, while tamper detection alerts security personnel to potential intrusion attempts.
Read In/Out
Full bidirectional credential verification for complete access audit trails.
Fire Alarm Input
Automatic emergency door release integrates with building fire alarm systems.
65K Cards
Support for 65,000 sequential credentials ensures capacity for enterprise deployments.
Tamper Alarm
Built-in tamper detection with dedicated alarm output protects against physical intrusion.
The CRC221-1 provides read-in/read-out control for one door (two readers per door), while CRC220 variants offer read-in with free-exit for multiple doors. Choose CRC221-1 when you need complete entry and exit credential verification.
Yes, by adding the TCP/IP-220 adaptor module, the CRC221-1 can communicate over existing Ethernet infrastructure while still allowing RS485 connection to up to 31 additional controllers.
The CRC221-1 is available in plastic enclosure (325 x 300 x 135mm) or metal enclosure (330 x 300 x 105mm), both including an integral 12V DC, 3A power supply and tamper switch.
Yes, the CRC221-1 stores up to 1,700 events (sequential mode) or 1,300 events (random mode) in non-volatile memory, automatically uploading to Norpass3 when connectivity is restored.
Enclosure models accept 240V AC mains power, which the integral PSU converts to 12V DC. Four individually fused 12V outputs power connected locking devices.
Case Studies
GET TRAINED. GET CONFIDENT. GET INSTALLING.
Related Products
CRC221-2 Online Two Door Controller
The CRC221-2 two-door controller is part of a range of versa...
CRC220-4 Online Four Door Controller
The CRC220-4 controllers is part of a range of versatile mod...
Norpass3 Access Control Software
Together with Nortech’s modular access control panels, Norpa...
TCP/IP-220 TCP/IP Adaptor
The TCP/IP-220 network adaptor enables management communicat...