3-Series Single Channel Vehicle Detector 1
3-Series Single Channel Vehicle Detector 2
3-Series Single Channel Vehicle Detector 3
3-Series Single Channel Vehicle Detector 1
3-Series Single Channel Vehicle Detector 2
3-Series Single Channel Vehicle Detector 3
Products / Inductive-Loop-Detectors / 3-Series Single Channel Vehicle Detector

3-Series Single Channel Vehicle Detector

PD130/PD131/PD132/PD134/PD139

'Reliability and Durability Combined'

Identifies the presence of vehicles by means of an inductive loop buried under the road. The range includes PD130, PD132, PD134, PD139, PD232, PD234 products

PRODUCT FEATURES & BENEFITS

These “single chip” microprocessor-based units benefit from a detect filter and frequency indicator and are suitable for parking control and motorised door or gate applications all detectors are CE tested and approved.

Single channel loop detectors are available in both boxed and PCB format.

A compact detector diagnostic unit is available for extracting data from new and existing sites.


features

  • Compact size
  • Diagnostic capabilities (when used with a DU100)
  • Selectable permanent presence (to eliminate premature barrier / gate closure)
  • Loop isolation protection
  • Loop frequency indication (to eliminate interference with adjacent loops)
  • Automatic sensitivity boost (ASB) – for reliable detection of high-bed vehicles (e.g. lorries)
  • Detect filter – for screening out unwanted inputs
  • Powerfail memory (optional) – to retain presence when power is restored
  • The range includes the following products: PD130, PD132, PD134, PD139, PD232, PD234

Specifications

Self tuning range: 20-1500μH
Sensitivity: 4 step adjustable

High: 0.02% ΔL/L;

Medium High: 0.05% ΔL/L;

Medium Low: 0.1% ΔL/L;

Low: 0.5% ΔL/L
Frequency: 4 step adjustable, 12-80kHz

(Frequency determined by loop geometry)
PD130 Output Relays: Presence output relay - Change-over contacts (fail-safe) rated at 5A @ 230V AC

Pulse output relay - Change-over contacts (non-fail-safe) rated at 5A @ 230V AC
PD139 Output Relay: Presence output relay - Change-over contacts (fail-safe) rated at 1A @ 230V AC

Pulse output relay - Change-over contacts (non-fail-safe) rated at 1A @ 230V AC
PD130 Pulse output duration: Approx. 150ms, factory option 250ms
PD139 Pulse output duration: Approx. 150ms
Presence time: 1 hour for 3% ΔL/L, permanent presence option
Protection: Loop isolation transformer, zener diode clamping on loop inputs and gas discharge tube protection
PD130 Power requirements: 120V AC +/- 15% 48-60Hz (PD131)

230V AC +/- 15% 48-60Hz (PD132)

12-24V AC/DC +/- 15% (PD134)
Current requirement: 1.5VA max @ 230V
PD139 Power requirements: 24V AC/DC +/- 15%
Current requirement: 1.1VA max @ 24V DC
Operating temp range: -40oC to +80oC (circuit sealed against condensation)
Material: PD130: High heat ABS blend
Dimensions (mm): PD130: 76 x 40 x 78;

PD139: 105 x 68
Mounting: PD130: Shelf or DIN-rail socket

PD139: Panel or plug-in
Connector: PD130: Single rear mount 11-pin submagnal (86CP11);

PD139: Molex 10-pin female
Option: Flying leads

Reliable Vehicle Detection for Gate and Barrier Control Applications

The 3-Series Single Channel Vehicle Detector delivers dependable performance for parking facilities, commercial entrances, and industrial sites where precise vehicle sensing is essential. Whether installed at warehouse loading docks, residential gate systems, retail parking barriers, or high-speed industrial doors, this microprocessor-based detector ensures consistent operation across demanding environments with temperatures ranging from -40°C to +80°C.

Site managers at corporate campuses and logistics centres rely on these detectors for their automatic sensitivity boost feature, which maintains accurate detection of both standard vehicles and high-bed lorries. The selectable permanent presence function prevents premature barrier closure—critical for sites with frequent vehicle throughput. Available in boxed (PD130) and PCB (PD139) formats, installation teams can choose the configuration that best suits their cabinet requirements, while the optional DU100 diagnostic unit enables performance verification without disrupting operations.

Reliable Vehicle Detection for Gate and Barrier Control Applications

<p><span>Auto-Tune</span><br>Self-tuning frequency eliminates manual calibration and prevents interference with adjacent loops.</p>

Auto-Tune
Self-tuning frequency eliminates manual calibration and prevents interference with adjacent loops.

<p><span>Wide Range</span><br>Operates from -40°C to +80°C with sealed circuits protecting against condensation.</p>

Wide Range
Operates from -40°C to +80°C with sealed circuits protecting against condensation.

<p><span>Flexible Output</span><br>Selectable presence or pulse modes with fail-safe relay contacts rated at 5A for direct barrier control.</p>

Flexible Output
Selectable presence or pulse modes with fail-safe relay contacts rated at 5A for direct barrier control.

<p><span>Diagnostic Ready</span><br>Compatible with DU100 diagnostic unit for non-disruptive performance monitoring and historical fault analysis.</p>

Diagnostic Ready
Compatible with DU100 diagnostic unit for non-disruptive performance monitoring and historical fault analysis.

Frequently Asked Questions
What voltage options are available for the 3-Series Single Channel detector? Frequently Asked Questions

The boxed PD130 series offers three voltage variants: PD131 operates on 120V AC, PD132 on 230V AC, and PD134 on 12-24V AC/DC. The PCB-based PD139 operates on 24V AC/DC, making it suitable for integration into existing barrier controller power supplies.

How does the Automatic Sensitivity Boost (ASB) function work? Frequently Asked Questions

ASB automatically increases detection sensitivity when a vehicle with high ground clearance (such as lorries or SUVs) enters the loop zone. This ensures reliable detection of vehicles that might otherwise fall below the standard sensitivity threshold, preventing false undetect events.

Can this detector be used with rising bollards and safety-critical applications? Frequently Asked Questions

Yes. The optional power fail memory feature retains vehicle presence status during power interruptions and detects vehicles that arrive while power is off, providing immediate detection when power restores. This is essential for rising bollard applications where undetected vehicles could cause damage.

What is the loop inductance range supported by this detector? Frequently Asked Questions

The detector self-tunes across a 20-1500μH inductance range, accommodating most standard loop configurations from small vehicle bays to larger entrance loops. The 4-step adjustable frequency (12-80kHz) allows fine-tuning based on specific loop geometry.

How is the detector mounted and what connectors are used? Frequently Asked Questions

The boxed PD130 mounts on a shelf or DIN-rail socket using an 11-pin submagnal connector (86CP11). The PCB-based PD139 uses panel or plug-in mounting with a Molex 10-pin female connector. Flying lead options are available for both variants.

GET TRAINED. GET CONFIDENT. GET INSTALLING.

Free product training from our UK based support engineers who designed and support these systems. Whether you're specifying for the first time or adding to your portfolio, we'll get your team up to speed - fast.