These “single chip” microprocessor-based units benefit from a detect filter and frequency indicator and are suitable for parking control and motorised door or gate applications all detectors are CE tested and approved.
Single channel loop detectors are available in both boxed and PCB format.
A compact detector diagnostic unit is available for extracting data from new and existing sites.
Connect
Contact Us
+44 (0)1633 485 533
Self tuning range: | 20-1500μH |
Sensitivity: | 4 step adjustable High: 0.02% ΔL/L; Medium High: 0.05% ΔL/L; Medium Low: 0.1% ΔL/L; Low: 0.5% ΔL/L |
Frequency: | 4 step adjustable, 12-80kHz (Frequency determined by loop geometry) |
PD130 Output Relays: | Presence output relay - Change-over contacts (fail-safe) rated at 5A @ 230V AC Pulse output relay - Change-over contacts (non-fail-safe) rated at 5A @ 230V AC |
PD139 Output Relay: | Presence output relay - Change-over contacts (fail-safe) rated at 1A @ 230V AC Pulse output relay - Change-over contacts (non-fail-safe) rated at 1A @ 230V AC |
PD130 Pulse output duration: | Approx. 150ms, factory option 250ms |
PD139 Pulse output duration: | Approx. 150ms |
Presence time: | 1 hour for 3% ΔL/L, permanent presence option |
Protection: | Loop isolation transformer, zener diode clamping on loop inputs and gas discharge tube protection |
PD130 Power requirements: | 120V AC +/- 15% 48-60Hz (PD131) 230V AC +/- 15% 48-60Hz (PD132) 12-24V AC/DC +/- 15% (PD134) |
Current requirement: | 1.5VA max @ 230V |
PD139 Power requirements: | 24V AC/DC +/- 15% |
Current requirement: | 1.1VA max @ 24V DC |
Operating temp range: | -40oC to +80oC (circuit sealed against condensation) |
Material: | PD130: High heat ABS blend |
Dimensions (mm): | PD130: 76 x 40 x 78; PD139: 105 x 68 |
Mounting: | PD130: Shelf or DIN-rail socket PD139: Panel or plug-in |
Connector: | PD130: Single rear mount 11-pin submagnal (86CP11); PD139: Molex 10-pin female |
Option: | Flying leads |